BOHUASend your drawing

Engineering guide

ISO 8062 Casting Tolerances: Drawing and RFQ Guide

A casting tolerance grade is not a standalone millimeter capability. To use a tolerance table correctly, the buyer and supplier need the applicable standard edition, nominal dimension, dimension type, casting condition and any individual drawing requirements. Quoting a grade without those inputs leaves the acceptance basis incomplete.

On this page
  1. Establish the Controlling Drawing Requirement
  2. Distinguish Total Width From Plus/Minus Notation
  3. How to Read an ISO 8062-3 Casting Tolerance Chart
  4. Separate As-Cast and Machined Features
  5. Bohua: CT8 and machined dimensions
  6. Compare Manufacturing Routes on Equal Terms
  7. Prepare the Inspection Plan With the RFQ
  8. FAQ

Establish the Controlling Drawing Requirement

The public scope of ISO 8062-3:2023 concerns general dimensional and geometrical tolerances and machining allowances for castings using indicated dimensions. Obtain the controlled standard used by the contract and confirm that its scope fits the drawing. This guide does not reproduce the standard's numerical tables.

Record the full designation and edition. Identify whether a requirement comes from a general note, an individual dimension, a geometrical control or a customer specification. If documents disagree, resolve precedence through the buyer's engineering process before accepting the order.

ISO 8062-3:2023 is the second edition. It uses dimensional casting tolerance grades (DCTG). Before you release a drawing based on CT8 capability, confirm the governing edition and use its grade notation in the callout.

Source: ISO 8062-3:2023, public scope and edition.

Source: DIN EN ISO 8062-3:2023-05, overview of DCTG terminology.

Distinguish Total Width From Plus/Minus Notation

A total tolerance width and a bilateral plus/minus value are not the same number. If a requirement explicitly centers a tolerance zone about the nominal value, the plus/minus magnitude is half of that total width. Do not assume a centered zone where the controlling requirement defines a different disposition.

When transferring a value from a standard, check the nominal-size band, boundary inclusion, grade, units and zone disposition. Have a second reviewer reproduce the lookup. A copied table that mixes total widths and plus/minus values can change the acceptance requirement even when the heading looks correct.

For a centered zone, use total width T = upper limit − lower limit and bilateral magnitude = T / 2. Keep all inputs in the same unit. The examples below are arithmetic only; they are not ISO table values or Bohua capability data.

Arithmetic examples for tolerance width; dimensions and deviations in millimeters
CaseNominal dimension (mm)Total width T (mm)Lower deviation (mm)Upper deviation (mm)Limits (mm)
Centered example1000.4−0.2+0.299.8 to 100.2
Zero-width arithmetic check100000100 to 100; mathematical equality only
Negative-width input100−0.4Not validNot validReject: upper limit cannot be below lower limit
Asymmetric example1000.4−0.1+0.399.9 to 100.3; not centered on 100

Zero width is a mathematical check, not a recommended production tolerance. Reject a negative total width. For an asymmetric zone, retain the specified upper and lower deviations; halving T does not recover them. Convert units before calculating.

How to Read an ISO 8062-3 Casting Tolerance Chart

CT9 is a casting tolerance grade, not a fixed number of millimetres. To look up a value, use the edition specified on the drawing and the nominal dimension of the feature.

  1. Record the standard edition and check whether the dimension is as cast, machined or a wall thickness.
  2. Find the nominal-size band and the specified grade in your controlled copy of the standard. Check which end of the size band is included.
  3. Check whether the listed value is a total tolerance width. Calculate plus/minus deviations only when the drawing specifies a centered zone.
  4. Review individual dimension requirements, geometrical controls and machining allowances separately.

For the current edition and scope, see the official ISO 8062-3:2023 catalogue page. For a calculation example, see total width and plus/minus notation. For a supplier capability discussion, see Bohua's as-cast and machined capability.

Send the standard edition, marked dimensions, delivery state and inspection requirements through the tolerance and drawing review request.

Separate As-Cast and Machined Features

A casting grade does not automatically establish a finished bore's position, a sealing face's flatness or a functional clearance. State the necessary controls for those features individually.

Drawing decisions when applying a general casting requirement
Feature groupDrawing/RFQ decisionEvidence to agree
General as-cast dimensionsApplicable general tolerance requirement and exceptionsLayout or other agreed dimensional inspection
Core-formed passages and local wallsLocation, minimum condition and inspection accessSection/measurement plan appropriate to the geometry
Machined bores, ports and datumsIndividual dimensions and geometrical controlsDefined datum setup, gauges or CMM plan
Sealing or mating facesFlatness, surface texture and final conditionDimensional and functional evidence required by the design
Stock for machiningRequired allowance and reference stateAllowance review before tooling release

For the allocation of as-cast and finished dimensions, use the casting and machining tolerance guide.

Bohua: CT8 and machined dimensions

At Bohua

Bohua’s confirmed as-cast tolerance is CT8. Key machined dimensions can reach ±0.02 mm where the drawing, feature and datum scheme allow. These statements describe different delivery states.

Bohua uses Hexagon Global S and NANO Metrology coordinate measuring machines. There are 16 vertical machining centers.

Confirmed capability statements and the project conditions to define
Delivery stateConfirmed capabilityRequired project definition
As castCT8 grade; not a single value in mmApplicable standard and edition, nominal-size band, feature, process, exceptions and inspection state
Key machined dimensions±0.02 mmSelected feature and dimension range, datum scheme, delivery state, inspection method and drawing acceptance

Send us the marked drawing so we can review the applicable features and size ranges with you. Set the limit for each selected feature and specify the dimensional report you need to verify it.

Bridge-type coordinate measuring machine on a granite table with a joystick controller in a bright inspection room
Coordinate measuring machine for dimensional inspection
Long aisle with yellow floor lines between rows of white CNC machining centers and stacked cast parts on a pallet
CNC machining centers along a central aisle

Review Bohua gravity casting capability and the quality control and inspection scope against the drawing.

At Bohua

For individually agreed critical as-cast dimensions, Bohua can reach approximately DCTG 6. For a nominal dimension above 63 mm and up to and including 100 mm, DCTG 6 corresponds to a total tolerance of 0.78 mm, or ±0.39 mm if centered on nominal.

Use this as a starting point for the drawing review, then confirm the size band and grade in the controlled ISO 8062-3:2023 table if that edition governs your order. Routine as-cast dimensions remain CT8.

Example reference: ISO 8062-3:2023, Table 7. The 0.78 mm total width is one standard value used to explain the selected-feature capability statement; it is not a Bohua measurement result.

Compare Manufacturing Routes on Equal Terms

Do not compare process accuracy through unrelated generic plus/minus ranges. Use the same nominal dimension, feature, geometry, alloy, process condition and inspection method. Ask the supplier to identify the proposed capability evidence and any design changes needed to support it.

Tool construction, core location, local section, heat treatment and machining sequence can affect the result. Separate a proposed target from demonstrated capability and from the customer's acceptance limit. A target printed in a quotation is not a completed capability study.

Prepare the Inspection Plan With the RFQ

Mark the nominal dimension and controlled feature, not only the overall part size.

  • Name the standard edition and any individual exceptions.
  • Define datums, part support and the inspection state.
  • Distinguish casting allowances from finished dimensions.
  • Identify inaccessible surfaces and how they will be verified.
  • Agree sample quantity, required reports and disposition of nonconforming results.

For a suspension bracket, carry those inputs into the suspension bracket RFQ requirements.

At Bohua

Bohua can support PPAP up to Level 5 when the dimensional evidence forms part of a customer approval package.

Agree the sample quantity, inspected state and required records with the PPAP submission scope.

FAQ

Can one general casting grade control every feature?

No. Review its scope and specify individual requirements for features that need different controls.

Can I copy a CT or DCTG number from a supplier brochure?

Only as a discussion starting point. Confirm the designation, edition, dimensions and applicability in the controlled drawing package.

Should every tight feature be machined?

That is a design and manufacturing decision. Compare the required function and acceptance with a verified route instead of inferring machining need from one general tolerance grade.

Send the marked drawing and inspection expectations through the tolerance RFQ route.

Send the drawing and standard edition

Send the controlled drawing, alloy, delivery condition, annual volume and required acceptance records. Submit the RFQ details, then email your drawing for a structured quote review. Send the drawing, target alloy, finishing scope, MOQ, and delivery timing. Bohua will review it like a real sourcing project, not a generic contact request. Our engineering team can recommend the right alloy, process, and design optimizations for your specific requirements.

Send your drawing →

Linda

Export Sales

linda@ningbobohua.com

Ningbo, Zhejiang, China